Lines Matching refs:icnss_pr_err

122 				icnss_pr_err("Regulator %s doesn't exist: %d\n",  in icnss_get_vreg_single()
131 icnss_pr_err("Failed to get regulator %s, err = %d\n", in icnss_get_vreg_single()
210 icnss_pr_err("Failed to set voltage for regulator %s, min_uv: %u, max_uv: %u, err = %d\n", in icnss_vreg_on_single()
222 icnss_pr_err("Failed to set load for regulator %s, load: %u, err = %d\n", in icnss_vreg_on_single()
234 icnss_pr_err("Failed to enable regulator %s, err = %d\n", in icnss_vreg_on_single()
260 icnss_pr_err("Failed to set load for regulator %s, err = %d\n", in icnss_vreg_unvote_single()
268 icnss_pr_err("Failed to set voltage for regulator %s, err = %d\n", in icnss_vreg_unvote_single()
290 icnss_pr_err("Failed to disable regulator %s, err = %d\n", in icnss_vreg_off_single()
296 icnss_pr_err("Failed to set load for regulator %s, err = %d\n", in icnss_vreg_off_single()
304 icnss_pr_err("Failed to set voltage for regulator %s, err = %d\n", in icnss_vreg_off_single()
329 icnss_pr_err("Unsupported device_id 0x%x\n", device_id); in get_vreg_list()
450 icnss_pr_err("Failed to get clock %s, err = %d\n", in icnss_get_clk_single()
480 icnss_pr_err("Failed to set frequency %u for clock %s, err = %d\n", in icnss_clk_on_single()
489 icnss_pr_err("Failed to enable clock %s, err = %d\n", in icnss_clk_on_single()
650 icnss_pr_err("Failed to turn on vreg, err = %d\n", ret); in icnss_hw_power_on()
699 icnss_pr_err("Invalid drvdata: dev %pK, data %pK\n", in icnss_power_on()
715 icnss_pr_err("Invalid drvdata: dev %pK, data %pK\n", in icnss_power_off()
796 icnss_pr_err("Failed to get qmp\n"); in icnss_aop_interface_init()
808 icnss_pr_err("Failed to reconfig WLAN PDC, err = %d\n", ret); in icnss_aop_interface_init()
853 icnss_pr_err("Failed to send AOP QMP msg: %s\n", mbox_msg); in icnss_aop_set_vreg_param()
863 icnss_pr_err("Failed to send AOP mbox msg: %s,ret: %d\n", in icnss_aop_set_vreg_param()
898 icnss_pr_err("Failed to send AOP QMP msg: %s\n", in icnss_aop_pdc_reconfig()
909 icnss_pr_err("Failed to send AOP mbox msg: %s,ret: %d\n", in icnss_aop_pdc_reconfig()
962 icnss_pr_err("Failed to get PDC Init Table\n"); in icnss_power_misc_params_init()
964 icnss_pr_err("Failed to alloc PDC Init Table mem\n"); in icnss_power_misc_params_init()
981 icnss_pr_err("Voltage %dmV is not valid\n", cpr_info->voltage); in icnss_update_cpr_info()
1008 icnss_pr_err("battery percentage read error:%d\n", err); in icnss_get_battery_level()
1028 icnss_pr_err("Battery percentage read failure\n"); in icnss_update_soc_level()
1046 icnss_pr_err("Unable to update ldo voltage"); in icnss_update_soc_level()
1076 icnss_pr_err("Workqueue creation failed for soc update\n"); in icnss_get_psf_info()
1084 icnss_pr_err("Power supply framework registration err: %d\n", in icnss_get_psf_info()